PVC Telecom Duct – 110 mm – Heavy Duty | OSP Network

PVC Telecom Duct 110 mm Heavy Duty

 OSP Network Conduit for Underground Fiber & Copper Cables in KSA & Gulf | High-Strength PVC Cable Protection

image

Features & Benefits

1. Heavy Duty Construction

  • The thick walls of PVC give top-class resistance against soil pressure, compaction, and accidental impacts.
  • These walls can even endure heavy-duty uses such as highways, industrial zones, and deep trenching installations.

2 Smooth Interior Surface

  • The friction is minimized for the installation of the fiber optic cables.
  • The installation of air-blown cables is facilitated which, in turn, enhances the effectiveness of the installation.

3 Corrosion & Moisture Resistance

  • The PVC material is impervious to water and air—which is why it is still a perfect choice for very damp places.

4 UV & Heats Resistant

  • It is possible to use in the places with hot countries and harsh sunlight like the Gulf region.
  • The material can tolerate very high temperatures without changing its properties.

5 Long Service Life

  • The product's life span is estimated in decades of protection which means no maintenance or replacement costs.

6 Compatibility

  • Fiber optic, copper, and hybrid cables are all supported.
  • Couplers, end caps, pull ropes, j-boxes, tracer wires, and warning tapes are all compatible.

7 Easy Handling & Installation

  • Field installation is not a problem, even with its heavy-duty design.
  • The product is suitable for urban, suburban, industrial, and highway environments.

Technical Specifications – PVC Telecom Duct 110 mm Heavy Duty

SpecificationDetails
Product NamePVC Telecom Duct – 110 mm Heavy Duty
MaterialRigid High-Grade PVC
Wall ThicknessHeavy duty, thick-walled
Internal Diameter110 mm
Outer Diameter~120–125 mm (manufacturer dependent)
Length3 m, 6 m, custom
End TypesBell & spigot or plain ends with couplers
ApplicationUnderground OSP fiber optic and copper cables
InstallationDirect burial, duct banks, roadsides, highways, industrial zones
Cable CompatibilityFiber optic, copper telecom cables
Temperature RangeHigh ambient temperatures (up to 60°C)
ResistanceSoil moisture, chemical corrosion, UV, mechanical impact
ComplianceTelecom industry standards for heavy-duty OSP installations

Why Choose 110 mm Heavy Duty Duct?

1 Maximum Protection for High-Traffic Zones

  • Thick walls resist mechanical stress, road load, and compaction

  • Ideal for highway crossings, industrial areas, and urban backbone networks

2 Suitable for High-Capacity Networks

  • 110 mm diameter allows multiple fiber or copper cables

  • Supports future network upgrades without additional excavation

3 Harsh Climate Resistance

  • UV-stabilized PVC and heat resistance make it perfect for KSA and Gulf region climates

4 Industrial & Backbone Network Applications

  • Can withstand heavy loads, making it suitable for utility corridors, industrial plants, and backbone OSP networks

Applications

  1. Highway & Roadside Installations: Heavy-duty protection for underground telecom cables
  2. Industrial & Commercial Projects: Reliable conduit for factories, commercial complexes, and power plants
  3. Urban Backbone Networks: Underground fiber deployment in high-capacity areas
  4. Residential FTTH / FTTx Deployments: Supports multiple fiber lines in large-scale housing projects
  5. Utility Corridors: Alongside power, water, or gas lines
  6. Campus Networks: Hospitals, universities, corporate offices requiring secure cable protection

Installation Guide

Step 1: Survey & Planning

  • Map route and check existing utilities

  • Determine trench depth, width, and spacing according to standards

Step 2: Trenching

  • Excavate trench to required depth

  • Lay sand bedding or soft soil to protect duct

Step 3: Laying the Duct

  • Lay ducts straight; avoid sharp bends

  • Use junction boxes or manholes for directional changes

Step 4: Coupling

  • Connect sections with bell & spigot or couplers

  • Ensure secure and watertight connection

Step 5: Pull Rope & Tracer Wire

  • Install pull ropes before cable installation

  • Lay tracer wire for future locating of ducts

Step 6: Cable Installation

  • Pull fiber optic or copper cables manually or via air-blown systems

Step 7: Backfilling

  • Fill trench with clean, compacted soil

  • Avoid rocks or debris that could damage the duct

Accessories

  1. couplers: Join several duct parts together
  2. End Caps: Shield ducts from dirt before the cable is placed
  3. Pull Ropes: Help in drawing cables
  4. Tracer Wires: Find ducts in the course of digging
  5. Junction Boxes / Manholes: Changes in direction and places to access
  6. Warning Tapes: Show the presence of underground ducts for safety reasons

Comparison – Light, Medium, and Heavy Duty PVC Ducts

FeatureLight DutyMedium DutyHeavy Duty
Wall ThicknessThinMediumThick
Load CapacityLowModerateHigh
Installation DepthShallowMediumDeep
Best UseSidewalks, micro ductsResidential, roadsidesHighways, deep trench, industrial zones
CostLowModerateHigher

110 mm heavy-duty ducts are essential for highway, industrial, backbone, and deep burial deployments, providing the highest level of protection for underground telecom cables.

Maintenance Tips

  • Inspect the open ends and put on end caps for sealing
  • For the sake of future location, keep tracer wires in good condition
  • Update the documentation of duct layout for any upgrades or repairs
  • Do not allow heavy machines to work directly over the ducts that have just been installed

Common Mistakes & How to Avoid Them

  • Inaccurate trench depth - adhere to telecom installation standards
  • No pull rope set up - insert pull ropes beforehand to facilitate cable deployment
  • Bends without junctions that are too sharp - install junction boxes to change the direction of cables
  • Backfilling that is not done properly - use clean, compacted soil as a protective barrier for ducts

Benefits of PVC Telecom Duct 110 mm Heavy Duty

  • Maximum protection against mechanical stress and soil pressure

  • Supports multiple cables for high-capacity networks

  • Long-lasting, UV & corrosion resistant, suitable for harsh climates

  • Ideal for highways, industrial zones, and backbone networks

  • Reduces maintenance and replacement costs

  • Compatible with all standard OSP accessories

Conclusion

The perfect option to shield instead of burying underground fiber optic and copper cables in the KSA and the Gulf countries' OSP networks is the PVC Telecom Duct – 110 mm Heavy Duty. Its toughness, complex piping, and ability to resist corrosion, among other features, allow installation in all types of environments, not only roads but also factories, deep burial cases, and backbone network installations.

The use of heavy-duty type 110 mm duct ensures the telecom industry in the Gulf region to have the triad of cable protection, long life, and the ability to grow with future demands, therefore, making them unavoidably necessary in telecom infrastructure projects.

Frequently Asked Questions (FAQs)

  1. What is PVC Telecom Duct 110 mm Heavy Duty used for?
    Protects underground fiber optic and copper cables in high-load OSP installations.

  2. Can it be buried under highways?
    Yes, it is designed for deep burial and high-traffic zones.

  3. Is it compatible with fiber optic cables?
    Yes, smooth interior ensures safe cable pulling and air-blown installation.

  4. How strong is a heavy duty 110 mm duct?
    Thick walls withstand soil compaction, rocks, and mechanical impacts.

  5. Can multiple cables fit inside one duct?
    Yes, depending on cable diameter and fill ratio standards.

  6. What accessories are required?
    Couplers, end caps, pull ropes, tracer wires, junction boxes, warning tapes.

  7. How does it differ from medium and light duty ducts?
    Heavy duty provides maximum load capacity, deep burial suitability, and long-term protection.

  8. Is it resistant to moisture and corrosion?
    Yes, PVC material is highly resistant to soil moisture and chemical corrosion.

  9. How long will this duct last?
    Decades with proper installation and maintenance.

  10. Is it suitable for Gulf and KSA climates?
    Yes, UV stabilized and heat resistant.