PVC Telecom Duct – 160 mm – Heavy Duty | OSP Network

PVC Telecom Duct 160 mm Heavy Duty

 OSP Network Conduit for Underground Fiber & Copper Cables in KSA & Gulf - High-Strength PVC Cable Protection

image

Features & Benefits

1 Heavy Duty Wall Construction

  • The robust PVC walls bring about the utmost mechanical strength for both soil pressure and accidental loads.
  • This is the ultimate solution for roadways, industrial areas, and even the installation of the main network.

2 Smooth Interior

  • The friction decreases when it comes to the installation of fiber optic cable.
  • Besides, the air-blown cable deployment is facilitated, thus the installation speed and efficiency are getting better.

3 Corrosion & Moisture Resistance

  • The PVC material is resistant to soil chemicals, moisture, and environmental degradation.

4 UV & Heat Resistant

  • The installation area is extremely hot and have high UV levels which is KSA and Gulf countries.

5 Long Service Life

  • Decades of reliable cable protection, and consequently, reduced maintenance and replacement costs.

6 Compatibility

  • The system is capable of fibers optic, copper and hybrid cables.
  • Moreover, it is completely compatible with the essential OSP accessories such as couplers, end caps, pull ropes, junction boxes, and tracer wires.

7 Ease of Installation

  • The heavy-duty design does not sacrifice efficient handling and field deployment.
  • The method of installation is suitable for urban, highway, industrial, and utility corridor installations.

Technical Specifications – PVC Telecom Duct 160 mm Heavy Duty

SpecificationDetails
Product NamePVC Telecom Duct – 160 mm Heavy Duty
MaterialHigh-Grade Rigid PVC
Wall ThicknessHeavy duty, thick-walled
Internal Diameter160 mm
Outer Diameter~180–185 mm (manufacturer dependent)
Length3 m, 6 m, or custom
End TypesBell & spigot or plain ends with couplers
ApplicationUnderground OSP fiber optic and copper cables
InstallationDirect burial, duct banks, roadsides, highways, industrial zones
Cable CompatibilityFiber optic, copper telecom cables
Temperature RangeUp to 60°C ambient temperature
ResistanceSoil moisture, chemical corrosion, UV, mechanical impact
ComplianceTelecom industry standards for heavy-duty OSP installations

Why Choose 160 mm Heavy Duty Duct?

1 Maximum Protection for Heavy Traffic and Industrial Zones

  • Thick walls resist soil compaction, mechanical stress, and accidental loads

  • Suitable for highway crossings, industrial plants, and urban backbone networks

2 High-Capacity Network Compatibility

  • 160 mm internal diameter accommodates multiple fiber or copper cables

  • Supports future network expansion without additional excavation

3 Harsh Climate Suitability

  • UV-stabilized and heat-resistant PVC ensures performance in hot, arid, and high UV regions

4 Backbone and Industrial Applications

  • Can withstand heavy loads in industrial, commercial, and critical network deployments

Applications

  • Highway & Roadside Installations: Strong protection for underground telecommunication cables
  • Industrial & Commercial Areas: Shielded conduit for factories, warehouses, and power
  • plants Urban Backbone Networks: Subsurface fiber for high-capacity network corridors
  • Residential FTTH / FTTx Deployments: Fiber support in extensive housing developments
  • Utility Corridors: Next to electricity, water, or gas pipelines
  • Campus Networks: Security cable protection for universities, hospitals, and corporate offices

Installation Guide

Step 1: Survey & Planning

  • Map route and check for existing utilities

  • Determine trench depth, width, and spacing according to telecom standards

Step 2: Trenching

  • Excavate trench to specified depth

  • Provide sand bedding or soft soil for duct protection

Step 3: Laying the Duct

  • Lay ducts straight and avoid sharp bends

  • Use junction boxes for directional changes

Step 4: Coupling

  • Connect duct sections using bell & spigot or couplers

  • Ensure watertight and secure connections

Step 5: Pull Rope & Tracer Wire

  • Install pull ropes before cable installation

  • Lay tracer wires to facilitate future locating of ducts

Step 6: Cable Installation

  • Pull fiber optic or copper cables manually or via air-blown systems

Step 7: Backfilling

  • Fill trench with clean, compacted soil

  • Avoid rocks or debris that could damage the duct

Accessories

  1. Couplers: Join together various sections of duct.
  2. End Caps: Shield the ducts from dirt and dust until the cable is installed.
  3. Pull Ropes: Help transported wires installation.
  4. Tracer Wires: Make the process of locating ducts during excavating easy.
  5. Junction Boxes / Manholes: Point of altering direction and entry.
  6. Warning Tapes: Show presence of underground ducts to avoid unintentional digging

Comparison – Light, Medium, and Heavy Duty PVC Ducts

FeatureLight DutyMedium DutyHeavy Duty
Wall ThicknessThinMediumThick
Load CapacityLowModerateHigh
Installation DepthShallowMediumDeep
Best UseSidewalks, micro ductsResidential, roadsidesHighways, deep trench, industrial zones
CostLowModerateHigher

160 mm heavy-duty ducts are ideal for critical network deployments, deep burial, industrial areas, and high-capacity backbones, offering the highest level of protection for underground telecom infrastructure.

Maintenance Tips

  1. Firstly, make sure to examine the exposed parts and then cover them with the end caps.
  2. Secondly, use the tracer wires as a guide for the future duct location.
  3. Thirdly, the duct layout documentation must be kept in case of network upgrades or repairs.
  4. Lastly, do not allow heavy machinery to operate over the recently installed ducts.

Common Mistakes & How to Avoid Them

  • Incorrect trench depth – adhere to telecom installation standards

  • No pull rope installed – pre-insert before cable deployment

  • Sharp bends without junctions – use junction boxes or manholes

  • Improper backfill – use clean, compacted soil to protect ducts

Benefits of PVC Telecom Duct 160 mm Heavy Duty

  • Ultimate defense against mechanical forces and earth pressure
  • Permits installation of several fiber or copper cables to cater high-capacity networks
  • Durable and resistant to UV and corrosion
  • Suitable for highways, industrial areas, and trunk networks
  • Lowers costs of maintenance and replacement
  • Works with all standard OSP accessories

Conclusion

The PVC Telecom Duct – 160 mm Heavy Duty ensures complete protection of underground fiber optic and copper cables in OSP networks across KSA and the Gulf. This duct, designed for heavy-duty use, has a thick wall that supports the entire duct system. The inner surface is smooth, allowing easy installation and maintenance. Moreover, the duct is resistant to corrosion and UV light and can still be compatible with all standard fittings. Thus, it can be used for any kind of installation such as highways, industrial areas, deep burial, or backbone network.

When you purchase 160 mm heavy-duty ducts, you are not only buying cable protection but also investing in the future because of the expected long-term durability and across-the-board scalability, which makes the heavy-duty ducts indispensable for the telecom infrastructure of the Gulf region and the projects of the future.

Frequently Asked Questions (FAQs)

  1. What is PVC Telecom Duct 160 mm Heavy Duty used for?
    Protects underground fiber optic and copper cables in high-load OSP installations.

  2. Can it be buried under highways?
    Yes, it is designed for deep burial and heavy traffic.

  3. Is it compatible with fiber optic cables?
    Yes, smooth interior ensures safe cable pulling and air-blown installation.

  4. How strong is a heavy duty 160 mm duct?
    Thick walls withstand soil compaction, rocks, and mechanical impacts.

  5. Can multiple cables fit inside one duct?
    Yes, depending on cable diameter and telecom fill ratio standards.

  6. What accessories are required?
    Couplers, end caps, pull ropes, tracer wires, junction boxes, warning tapes.

  7. How does it differ from medium and light duty ducts?
    Heavy duty provides maximum load capacity, deep burial suitability, and long-term protection.

  8. Is it resistant to moisture and corrosion?
    Yes, PVC material is highly resistant to soil moisture and chemical corrosion.

  9. How long will this duct last?
    Decades with proper installation and maintenance.

  10. Is it suitable for Gulf and KSA climates?
    Yes, UV stabilized and heat resistant.