HDPE PE100 Main Duct Full Black 250 mm – PN 16

HDPE PE100 Main-Duct 250mm PN 16

 Heavy-Duty Pressure Duct for Telecom, Water & Utility Networks in GCC

image

Key Features of HDPE PE100 Main-Duct Full Black 250 mm – PN 16

1. High-Strength PE100 Grade Material

PE100 provides:

  • Maximum pressure resistance
  • Extremely high tensile strength
  • Excellent crack resistance
  • Long lifetime even in harsh climates

2. Large 250mm Outer Diameter

Ideal for:

  • Main telecom conduit
  • Power cable bunches
  • Multi-duct passages
  • Large water networks

3. PN16 Pressure Rating

Rated for 16 bar pressure handling, suitable for:

  • Industrial water pipelines
  • High-pressure utilities
  • District cooling systems

4. UV-Resistant, Full Black Design

Very good for GCC climate because of:

  • UV blockers
  • Heat stabilizers
  • Anti-aging agents

5. Smooth Internal Bore

Allowing:

  • Fiber blowing over long distances
  • Cable pulling with very low friction

6. Corrosion-Free Material

Not affected by:

  • Coastal salinity
  • Harsh soils
  • Chemical exposure
  • Oxidation

7. Flexible, Lightweight & Easy to Install

Compared to concrete or metal ducts, HDPE is:

  • Impact resistant
  • Flexible when bending
  • Light and easy to move around

8. 50+ Years Service Life

Offers:

  • Very low replacement cost
  • Less maintenance times
  • Long term infrastructure reliability

Technical Specifications – HDPE PE100 Main-Duct 250 mm PN 16

ParameterSpecification
MaterialHigh-Density Polyethylene (PE100)
Outside Diameter (OD)250 mm
Pressure ClassPN 16 (16 bar)
ColorFull Black, UV Stabilized
StandardISO 4427, EN Standards, GCC Utility Standards
Length Options6m, 12m, or coil (as required)
Density≥ 950 kg/m³
Temperature Range-20°C to +80°C
FlexibilityHigh
UV ResistanceExcellent
Chemical ResistanceExcellent
Joining MethodButt-fusion, electrofusion, flange joint
Life Expectancy50+ years

Applications of HDPE PE100 Main-Duct 250 mm – PN 16

1. Telecom & Fiber Optic Infrastructure

Widely used for:

  • Fiber trunk routes

  • 5G network backbone

  • Inter-city OFC networks

  • Mega data center connectivity

  • Smart city communication grids

The 250mm diameter allows high fiber capacity for future expansion.


2. High-Voltage Electrical Cable Protection

Suitable for:

  • HV/MV electrical transmission

  • Power distribution corridors

  • Renewable energy farms

  • Substation-to-grid connections

HDPE ensures the cables are safe from water, soil pressure, and corrosion.


3. High-Pressure Water Pipelines

With PN16 rating, it is used for:

  • Drinking water networks

  • Industrial water supply

  • District cooling pipelines

  • Irrigation systems

  • Treated water distribution


4. Oil, Gas & Petrochemical Facilities

Used for:

  • Cable conduits in refineries

  • Utility corridors in oil plants

  • Industrial effluent transfer

  • Chemical-resistant pipeline ducting


5. Mega Infrastructure Projects

Ideal for:

  • Metro rail lines

  • Airports

  • Highways

  • Tunnels

  • SEZ industrial zones

  • Utility clusters in mega developments

Why 250mm PN16 HDPE PE100 Duct is Best for GCC Region

1. Survived Extreme Desert Conditions

The unit still works flawlessly even in the most challenging situations in the following ways:

  • temperatures above 50°C
  • very high UV
  • very hot and dry winds coming through the desert
  • very fine sand rubbing against it

2. Total Rusting Prevention

This is the perfect place for coast regions near the sea like:

  • the Red Sea coast
  • the Arabian Gulf coast

3. Great for Rapidly Developing Infrastructures

  • The system is a backer for:
  • high-density cable routes
  • urban area development plans
  • national projects for digital and communication transformation

4. Fit for No-Dig Technology

  • Is compatible and does not cause any issues with:
  • horizontal directional drilling (HDD)
  • micro-tunneling
  • pipe jacking

5. Stability in Long-Term

The pipe network has been stable for many years and is in slow chemically aggressive areas.

How the HDPE PE100 Main-Duct 250 mm PN 16 is Used

1. Trench Installation

Used for general utility routing:

  • Dig trench

  • Lay duct

  • Add bedding material

  • Backfill in layers


2. Trenchless Installation (HDD)

Major applications:

  • Road crossings

  • Rail crossings

  • Water channels

  • Urban non-disruptive installations

The duct’s flexibility improves HDD success rate.


3. Cable Pulling & Fiber Blowing

The smooth internal bore:

  • Reduces friction

  • Supports high-speed blowing

  • Prevents cable stress


4. Industrial Pipeline Applications

Used for:

  • Water transport

  • Treated sewage

  • Chemical lines

  • Cooling systems

Advantages of HDPE PE100 250mm PN16 Main-Duct

✔ Extremely high strength when pressed
✔ Total immunity to rust
✔ UV protection of Gulf climate
✔ Areas of impact and cracking resistance
✔ Good for installation of cables over long distances
✔ Weighing less compared to concrete or metal
✔ Very flexible and suitable for rough terrains
✔ Can be used underground as well as on the surface
✔ Excellent hydraulic and airflow characteristics
✔ Unusually long service life (more than 50 years)

GCC-Focused Benefits

Saudi Arabia

Used in:

  • NEOM

  • ROSHN housing projects

  • Riyadh metro utility ducts

  • Water transmission lines

UAE

Used in:

  • Telecom ducting for Dubai Digital Network

  • Abu Dhabi industrial corridors

  • Etisalat & Du fiber tunnels

Qatar

Used for:

  • High-capacity cable ducting

  • Ashghal water networks

Kuwait, Oman & Bahrain

Used in:

  • Power grid modernization

  • Utility tunnels

  • Coastal industrial zones

Installation Guidelines

1. Storage & Delivery

  • Store in a shaded area
  • Do not keep it in darkness for a long time
  • Avoid sharp edges and heavy impacts

2. Welding Methods

  • Butt fusion
  • Electrofusion
  • Flanged joints

3. Bending Radius

Respect the maximum bending radius to avoid stressing the cable.

4. Backfilling

Soft soil or sand should be applied to minimize the damage.

5. Cable Installation Considerations

  • Use rollers
  • Avoid sharp bends
  • Blowing fiber for long distances

Conclusion

The HDPE PE100 Main-Duct Full Black 250 mm – PN 16 is the optimum choice for the region's telecom, utility, and industrial networks, and the overall infrastructure developments. Its great compatibility with extreme environments, such as the desert, is based on its excellent PE100 strength, PN16 pressure rating, UV-stabilized formulation, and corrosion-free performance.

The 250mm wide duct can accommodate high-carrying cable routes besides the industrial pipelines and utility growth that are the modern smart cities' critical elements. No matter the application—telecom backbone fiber or power cable protection, pressurized water lines, or mega construction—this duct works well, gives a long life, and needs almost no m...

This duct is still among the most trusted and cost-effective options for high-pressure and high-capacity infrastructure applications in Saudi Arabia, UAE, Qatar, Oman, Kuwait, and Bahrain.

Frequently Asked Questions (FAQs)

1. What is the main use of 250mm PN16 HDPE PE100 duct?
For telecom backbone, power cable protection, and high-pressure water pipelines.

2. Is it suitable for Gulf climate?
Yes, it is UV-stabilized and heat resistant.

3. What does PN16 mean?
It supports up to 16 bar internal pressure.

4. Can it be installed using HDD?
Yes, HDPE PE100 is ideal for trenchless technology.

5. Is it corrosion-proof?
Completely corrosion and chemical resistant.

6. What is the expected lifespan?
50 years minimum.

7. Can it be used for fiber optic cables?
Yes, especially for trunk and backbone routes.

8. Is the 250mm size suitable for power cables?
Yes, it supports HV and MV cable routes.

9. Does it comply with GCC standards?
Yes, meets ISO and Gulf utility standards.

10. Is installation easy?
Yes, it is lightweight, flexible, and easy to weld.