Premium Telecom duct for Fiber Optic Networks in KSA & Gulf
The HDPE PE100 Mini-Duct Full Black 50/40.8 mm is a fiber optic duct that provides the assurance of being secure, sturdy, and lasting for several years as a telecom cable path. It has an outer diameter of 50 mm and an inner diameter of 40.8 mm designed for the efficient pulling or blowing of cables in medium- to long-distance routes of fiber optics.
The duct is made of PE100 High-Density Polyethylene, which is the most advanced HDPE grade in the telecom area. It has the following advantages:
The solid black color indicates the designation of telecom and contributes to the duct’s characteristic of being fully protected against UV rays which in turn makes it the best fit for the extreme heat and dryness of the Gulf region.
The HDPE PE100 Mini-Duct Full Black 50/40.8 mm is a single-wall smooth duct used for underground fiber optic cable protection. Designed with a smooth internal bore, it enables effortless cable movement during installation. The black color provides natural UV stabilization, further enhanced by carbon black additives.
This duct is suitable for:
Direct Burial
Micro-Trenching
Horizontal Directional Drilling (HDD)
Duct-in-Duct installation
Road-crossing telecom lines
Smart city fiber networks
5G backbone fiber routes
The HDPE PE100 Mini-Duct Full Black 50/40.8 mm is a fiber optic duct that provides the assurance of being secure, sturdy, and lasting for several years as a telecom cable path. It has an outer diameter of 50 mm and an inner diameter of 40.8 mm designed for the efficient pulling or blowing of cables in medium- to long-distance routes of fiber optics.
The duct is made of PE100 High-Density Polyethylene, which is the most advanced HDPE grade in the telecom area. It has the following advantages:
The solid black color indicates the designation of telecom and contributes to the duct’s characteristic of being fully protected against UV rays which in turn makes it the best fit for the extreme heat and dryness of the Gulf region.
The HDPE PE100 Mini-Duct Full Black 50/40.8 mm is a single-wall smooth duct used for underground fiber optic cable protection. Designed with a smooth internal bore, it enables effortless cable movement during installation. The black color provides natural UV stabilization, further enhanced by carbon black additives.
This duct is suitable for:
Direct Burial
Micro-Trenching
Horizontal Directional Drilling (HDD)
Duct-in-Duct installation
Road-crossing telecom lines
Smart city fiber networks
5G backbone fiber routes

The 50/40.8 mm size is widely used in the Gulf for backbone telecom routes and FTTH distribution layers. It supports:
Blown fiber systems
Medium-sized fiber optic cables
Multi-core fiber routing
Duct-in-duct upgrades
Its diameter allows installers to achieve high blowing distances without excessive friction, which is critical in large-scale projects across Riyadh, Jeddah, Dubai, Doha, Muscat, and Kuwait City.
Composed solely of the PE100 HDPE type
The performance of the PE100 HDPE type is much stronger and has a much longer lifespan compared to the others like the PE80 and the ones made from other polymers.
Smooth Inner Bore
On installation, blowing fiber for long distance becomes easier and takes less time.
Resistance to UV & Weather Conditions
The Gulf region's sunniest and the desert's harshest conditions are no longer a very big challenge.
High Flexibility
This means that the installation could be carried out without any problems in the areas with bends, in the mountains, and through complicated duct routes.
Incredible Crush Resistance
The product has been engineered to withstand the combined forces of road loads, soil pressure, and construction impact as well as trench compaction.
Lifespan of Over 50 Years
Reliable networks are ensured by minimal maintenance.
Non-Conductive Electrically
The telecommunications would be risk-free and no signal quality would be affected.
Moisture & Chemical Resistant
Fiber cables will be safe from getting soaked with salts, moisture, and hydrocarbons that are often found in Gulf soil.
Below is a detailed specification profile required for documentation, procurement, quality assurance, and consultant approvals.
| Parameter | Details |
|---|---|
| Product | HDPE PE100 Mini-Duct Full Black |
| Outer Diameter (OD) | 50 mm |
| Inner Diameter (ID) | 40.8 mm |
| Material Grade | PE100 (High-Density Polyethylene) |
| Color | Full Black |
| Identification | Full Black for Telecom Applications |
| Internal Surface | Smooth Bore |
| UV Stability | Yes, Carbon-Black Enhanced |
| Coil Length | 50m / 100m / 200m / 300m / 500m / Custom |
| Usage | Fiber Optic Cable Protection |
| Property | Performance |
|---|---|
| Tensile Strength | > 25 MPa (Typical PE100 Requirement) |
| Elongation at Break | High |
| Impact Resistance | Excellent (Drop, Crush & Impact Resistant) |
| Flexibility | High |
| Ring Stiffness | High (Suitable for Deep Burial) |
| Property | Rating |
|---|---|
| Operating Temperature | -30°C to +60°C |
| Melting Point | > 130°C |
| Heat Resistance | Suitable for Desert Climate |
| Thermal Expansion | Low |
| Chemical | Performance |
|---|---|
| Acids | Resistant |
| Alkalis | Resistant |
| Salts | Highly Resistant |
| Hydrocarbons | Stable |
| Water | 100% Waterproof |
Used for last-mile fiber distribution and house drop cable protection.
Supports large fiber bundles along highways and intercity corridors.
Required for high-capacity fiber backhaul connecting 5G towers.
Used in IoT, traffic systems, CCTV, and connected city networks.
Ideal for fiber routing between data centers and network exchange points.
Perfect for narrow trench cuts in urban environments like Riyadh, Dubai & Doha.
Universities, airports, industrial zones, and hospitals.
Used for telecom signal corridors, ITS systems, metro fiber lines.
The harsh Middle Eastern environment demands superior materials. This duct is engineered for:
Withstands ambient temperatures up to 60°C.
Black color + UV stabilizers protect the duct for decades.
Coastal areas like Dammam, Abu Dhabi & Doha benefit from chemical resistance.
High-density HDPE resists erosion from moving sand.
Ideal for deep burial in desert and highway projects.
1. Direct Burial
The direct burial method is the most common technique used in Gulf telecom projects. A duct is set up in a trench and afterward, it is covered again with soil.
2. Open-Cut Trenching
This technique is suitable for routes of very long distances.
3. Micro-Trenching
Micro-trenching is gaining acceptance in Riyadh, Abu Dhabi, Dubai, and Doha for urban fiber expansion.
4. HDD (Horizontal Directional Drilling)
HDD is used for:
5. Duct-in-Duct Installations
Such installations are very much suited for the purpose of upgrading the old telecom networks.
6. Aerial Installations
In rural areas, aerial installations can be tied on to poles.
Lightweight yet strong.
Smooth bore allows long cable blowing distances.
PE100 lasts more than 50 years, reducing the need for replacements.
Long coils reduce splice joints, increasing network reliability.
Matches IEC, ISO & EN standards widely required in Gulf projects.
The duct meets or exceeds:
ISO 4427 – HDPE Pipes
ISO 9001 – Quality Management
EN 12201 – HDPE Specifications
BS EN 61386 – Conduit Protection
IEC Fiber Optic Standards
Many project consultants in the Gulf allow or require similar specifications for telecom infrastructure.
Available in:
Coils (50m, 100m, 200m, 300m, 500m)
Wooden drums (for export)
Palletized bundles
Customized packaging
Suitable for export to KSA, UAE, Qatar, Oman, Kuwait & Bahrain.
Let's discuss the following features:
Outer and Inner Diameter
The measurement of 50/40.8 mm is excellent for the major medium-sized trunk lines.
Internal Surface
The smooth surface is an ideal option for blowing fiber over long-distance networks.
Material
PE100 gives the best performance for the longest lifetime.
UV Resistance
It is necessary for projects in the Gulf region.
Certification
It is a proof of compliance with the ISO/EN telecom standards.
Coil Length
Longer coils mean fewer joints, which in turn increases the reliability of the network.
The HDPE PE100 Mini-Duct Full Black 50/40.8 mm has been specifically engineered to ensure optimal telecom performance in the Gulf region. The application of the top-quality PE100 substance has led to the development of a tube that is difficult to destroy by heat, has high UV resistance, and can last for a long time. Hence, it is the perfect solution for FTTH networks main routes, 5G backhaul, and smart city fiber deployments.
The microduct is the great option if your project needs a duct that can withstand the harsh Middle East climate while delivering the kind of reliability that has never been seen before.
For fiber optic cable protection in telecom networks.
Yes — it is UV-stabilized and heat-resistant.
Yes, it is designed for direct burial.
Blowing and HDD are commonly used.
Yes — it offers higher strength and durability.
More than 50 years.
Yes — 100% moisture-proof.
Absolutely, it's ideal for narrow trench installations.
Yes — suitable for curved routes.
Yes, it matches telecom specifications required by major Gulf consultants.