Concrete Encased Electrical Conduit for KSA & Gulf Underground Wiring
The PVC Type EB-20 Conduit – 160 mm (6″) | Concrete Encased has been developed to bring excellent protection and to withstand for long time underground electrical installations in the Kingdom of Saudi Arabia and the Gulf area. It is very large with a diameter of 160 mm which makes it suitable for the installation of high-capacity power feeders, utility corridors, and large industrial projects.
This conduit that has been designed for concrete encasement only protects the wires from mechanical stress, soil pressure, moisture, and even chemical exposure. The canal made of rigid PVC assures electrical safety, no corrosion, and structural reliability even in the most extreme desert climates of the Gulf region.
And, it is fast becoming the go-to option in housing, commercial, industrial, and municipal projects as it provides engineers and contractors with a solution that is not only cost-effective but also safe and durable for a long time to come in the matter of underground cabling requirements.
The PVC Type EB-20 Conduit – 160 mm (6″) is a medium-duty conduit optimized for concrete encasement applications. The EB-20 classification ensures mechanical protection and durability while maintaining ease of installation and cost efficiency.
Key Highlights:
Manufactured from high-quality rigid PVC for impact and chemical resistance
Non-conductive material ensures electrical safety
Smooth internal bore for hassle-free cable pulling
Designed for heavy-duty infrastructure and utility projects
Fully compatible with PVC couplers, bends, and junction boxes
Its large 160 mm diameter supports multiple cable runs, making it suitable for industrial, commercial, and high-demand residential networks.
The PVC Type EB-20 Conduit – 160 mm (6″) | Concrete Encased has been developed to bring excellent protection and to withstand for long time underground electrical installations in the Kingdom of Saudi Arabia and the Gulf area. It is very large with a diameter of 160 mm which makes it suitable for the installation of high-capacity power feeders, utility corridors, and large industrial projects.
This conduit that has been designed for concrete encasement only protects the wires from mechanical stress, soil pressure, moisture, and even chemical exposure. The canal made of rigid PVC assures electrical safety, no corrosion, and structural reliability even in the most extreme desert climates of the Gulf region.
And, it is fast becoming the go-to option in housing, commercial, industrial, and municipal projects as it provides engineers and contractors with a solution that is not only cost-effective but also safe and durable for a long time to come in the matter of underground cabling requirements.
The PVC Type EB-20 Conduit – 160 mm (6″) is a medium-duty conduit optimized for concrete encasement applications. The EB-20 classification ensures mechanical protection and durability while maintaining ease of installation and cost efficiency.
Key Highlights:
Manufactured from high-quality rigid PVC for impact and chemical resistance
Non-conductive material ensures electrical safety
Smooth internal bore for hassle-free cable pulling
Designed for heavy-duty infrastructure and utility projects
Fully compatible with PVC couplers, bends, and junction boxes
Its large 160 mm diameter supports multiple cable runs, making it suitable for industrial, commercial, and high-demand residential networks.

| Specification | Details |
|---|---|
| Product Type | PVC Type EB-20 Conduit |
| Nominal Diameter | 160 mm (6″) |
| Installation | Concrete Encased |
| Material | Rigid PVC |
| Duty Class | EB-20 (Medium Duty) |
| Standard Lengths | 3 m / 6 m |
| Color | Grey |
| Internal Surface | Smooth Bore |
| Operating Temperature | −10°C to +60°C |
| Electrical Property | Non-conductive |
| Corrosion Resistance | Excellent |
| Fire Rating | Self-extinguishing |
| Compliance | ASTM, IEC, GCC standards |
| Service Life | 30–50+ years |
Main power distribution networks
Residential, commercial, and industrial foundations
Utility duct banks and service corridors
Instrumentation and control wiring
Parking structures and basements
Industrial facilities and municipal infrastructure
Substations and high-capacity underground electrical installations
Site Assessment & Layout – Determine conduit route as per approved engineering drawings
Trench or Slab Preparation – Ensure proper alignment, slope, and bedding
Conduit Placement – Lay the EB-20 conduit in the prepared trench or foundation
Jointing – Use solvent weld or mechanical couplers to connect sections securely
Concrete Encasement – Pour concrete to fully protect the conduit and maintain structural integrity
Cable Pulling – After curing, cables can be pulled through the smooth bore effortlessly
PVC couplers (straight)
45° and 90° bends
Junction and inspection boxes
Solvent cement for jointing
Spacers, clamps, and support brackets
| Feature | PVC EB-20 160 mm | GI Conduit | HDPE |
|---|---|---|---|
| Concrete Compatibility | Excellent | Moderate | Limited |
| Corrosion Resistance | Excellent | Poor | Excellent |
| Electrical Safety | High | Medium | High |
| Installation Cost | Low | High | Medium |
| Service Life | 30–50+ yrs | 15–25 yrs | 25–40 yrs |
The PVC Type EB-20 Conduit – 160 mm (6″) | Concrete Encased is an excellent solution for high-capacity underground electrical installations in Saudi Arabia and the Gulf region since it is durable, reliable, and compliant with the code.
As its mechanical strength, corrosion resistance, non-conductivity, and long service life make it the preferred choice for modern infrastructure projects such as residential, commercial, industrial, and municipal installations, the use of EB-20 160 mm guarantees the safety, cost-effectiveness, and longevity of protection for your electrical network that is completely in line with the regional construction and electrical standards.
1. What is PVC Type EB-20 160 mm conduit used for?
It is designed for concrete-encased underground electrical installations, ideal for high-capacity cables.
2. Can EB-20 160 mm conduit be directly buried?
No. EB-20 160 mm is specifically engineered for concrete encasement.
3. Why choose 160 mm EB-20 conduit?
It supports multiple large cables, making it suitable for main feeders and industrial electrical networks.
4. Is PVC EB-20 safe for electrical installations?
Yes, it is non-conductive, providing maximum electrical safety.
5. Does EB-20 resist corrosion and moisture?
Yes, it is highly resistant to rust, chemical attack, and moisture.
6. Can EB-20 perform in Gulf climates?
Yes, it withstands extreme heat, desert conditions, and saline soils.
7. Which standards does EB-20 160 mm comply with?
It adheres to ASTM, IEC, and GCC electrical standards.
8. Is cable pulling easy inside EB-20 conduit?
Yes, its smooth internal surface ensures effortless cable installation.
9. What is the expected service life of EB-20 160 mm conduit?
Typically 30–50+ years with proper installation.
10. Where is EB-20 160 mm commonly used in KSA & Gulf projects?
In residential, commercial, industrial, and municipal infrastructure, including substations, duct banks, and main distribution lines.